To accommodate your complete servo system requirements, Glentek manufactures a complete line of isolation power transformers. The transformers are offered in both single phase and three phase versions. The single phase versions range from 1-2 KVA while the three phase transformers range from 3-9 KVA of continuous power. Many specialty transformers are stocked, however their specifications are not listed on this page. Please feel free to contact a Glentek Applications Engineer to assist you in making the proper transformer selection.

Isolation Power Transformers are primarily used for the following reasons:
1) They add isolation for safety purposes between the main power line and your servo system.
2) They add impedance to the line thereby reducing high frequency voltage fluctuations.
3) They reduce or transform the main line voltage to a lower, optimum level for servo systems.

Single Phase Transformers

Single Phase Transformers

*NOTE: A Single Phase 120VAC 5 amp max. winding is also provided on these transformers

Model Number KVA Primary VAC Secondary VAC Dimensions in Inches (mm) Weight
W L H ML MW Lbs (kg)
T320 1 120/240 32/46/50 5.6 (142) 4.4 (112) 5.3 (135) 3.45 (88) 4.5 (114) 22 (10)
T402TB 1 120/240 22/36/40 5.6 (142) 4.4 (112) 5.3 (135) 3.45 (88) 4.5 (114) 22 (10)
T408TB 1 120/240 85/95/106 5.6 (142) 4.4 (112) 5.3 (135) 3.45 (88) 4.5 (114) 22 (10)
T295TB* 1.4 120/240 50/50 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
T298TB 1.4 120/240 62/69/76 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
T314TB 1.4 120/240 72/79/86 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
T403TB 1.4 240/480 65/75/85 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
T564TB 1.4 120/240 120/140/160 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
T591TB 1.4 380/460 65/75/85 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
T657TB* 1.4 120/240 25/25/34/34 6.5 (165) 4.4 (112) 6.4 (163) 3.5 (89) 5.5 (140) 26 (12)
*NOTE: A Single Phase 120VAC 5 amp max. winding is also provided on these transformers

Three Phase Transformers

Three Phase Transformers

*NOTE: A Single Phase 120VAC 5 amp max. winding is also provided on these transformers

Model Number KVA Primary VAC Secondary VAC Dimensions in Inches (mm) Weight
W L H ML MW Lbs (kg)
T378TB* 3 240/480 85/106/117 8 (203) 11 (279) 9 (229) 5.15 (131) 6 (152) 72 (33)
T400TB* 3 240/480 63/74/85 8 (203) 11 (279) 9 (229) 5.15 (131) 6 (152) 72 (33)
T524TB* 3 240/480 120/140/160 8 (203) 11 (279) 9 (229) 5.15 (131) 6 (152) 72 (33)
T345TB* 6 240/480 85/106/117 8 (203) 14 (356) 9 (229) 5.15 (131) 6 (152) 115 (52)
T409TB* 6 240/480 63/74/85 8 (203) 14 (356) 9 (229) 5.15 (131) 6 (152) 115 (52)
T525TB* 6 240/480 120/140/160 8 (203) 14 (356) 9 (229) 5.15 (131) 6 (152) 115 (52)
T419TB* 9 240/480 85/106/117 9 (229) 18 (457) 13.5 (343) 6.8 (173) 16 (406) 195 (88)
T551TB* 9 240/480 120/140/160 9 (229) 18 (457) 13.5 (343) 6.8 (173) 16 (406) 195 (88)